Flow Rate 0.8 M/min -150 M/min
Alternative with : Domnick Hunter, Zender, Ultra Filter, Hiross, Hankison, Orion, Atlas Copco, CTA, Friulair etc
To ensure the highest performance efficiency, elements are put to test on our facility which employs a mono-dispersed aerosol to challenge the elements and a near forward light scattering technique to measure and confirm particle retention efficiency.
All compressed air filter elements are manufactured in accordance with ISO 8573.1:2001 (E)
| Compressed Air Quality to ISO 8573 Part 1:2001 |
| CLASS |
Maximum number of Solid Particle per m3 |
Water Pressure Dewpoint °C |
IOIL mg/m3 |
| 0.1-0.5 um |
0.5-1.0 um |
1.0-5.0 um |
| 1 |
100 |
1 |
0 |
-70 |
0.01 |
| 2 |
100,000 |
1,000 |
10 |
-40 |
0.1 |
| 3 |
- |
10,000 |
500 |
-20 |
1 |
| 4 |
- |
- |
1,000 |
3 |
5 |
| 5 |
- |
- |
20,000 |
7 |
25 |
| 6 |
- |
- |
- |
10 |
- |
SPECIFICATION :
| SPECIFICATION (standard) |
X25 (25 Micron) |
X3 (3 Micron) |
X1 (1 Micron) |
XA (0.01 Micron) |
AC (Activate Carbon) |
| Maximum partical size to ISO 8573.1 class |
4 |
3 |
2 |
1 |
1 |
| Maximum Oil content to ISO 8573.1 class |
5 |
4 |
2 |
1 |
1 |
| Particle removal |
25 micron |
3 micron |
1 micron |
0.01 micron |
N/A |
| Maximum oil carryover at 20°C(68°F) |
10 mg/m |
10 ppm |
3 mg/m |
3 ppm |
0.1 mg/m |
0.1 ppm |
0.01 mg/m |
0.01 ppm |
0.003 mg/m |
0.003 ppm |
| Maximum temperature |
120°C |
248°F |
120°C |
248°F |
120°C |
248°F |
120°C |
248°F |
25°C |
77°F |
| Pressure loss-clean & dry |
30mbar |
0.4psi |
0mbar |
0.6psi |
75mbar |
1.1psi |
100mbar |
1.5psi |
75mbar |
1.1psi |
| pressure oil saturated |
50mbar |
0.7psi |
75mbar |
1.1psi |
150mbar |
2.2psi |
300mbar |
4.4psi |
see notes |
| pressure loss-change element |
400mbar |
6psi |
400mbar |
6psi |
400mbar |
6psi |
400mbar |
6psi |
see notes |
| Maximum recommended pressure differential for element change |
- |
- |
340-400 mbar |
5-10psi |
- |
- |
- |
- |
- |
- |
| Element end cap |
HIGH GRADE ALUMINIUM |